Here is a list of recommended sensor to use with the Azeti solution. This list is only a recommendation, as any sensor that is compatible with the protocols supported can be used.
...
- MODBUS TCP
- MODBUS RTU/ASCII
- Digital Inputs
- Sink/source inputs (dry/wet contacts)
- Relay outputs
- Analogue Inputs
- 4-20 mA
- 0-5/10 Volt
- UDP Data
- TCP Sockets
Input/Output Modules
Modbus RTU
Vendor | Device | Comment | Connects via | Power |
Advantech | ADAM-4051-BE | 16 Digital Inputs | RS485 MODBUS | DC 24V |
Advantech | ADAM-4117-AE | 8 Analogue Inputs | RS485 MODBUS | DC 24V |
Advantech | ADAM-4150-AE | 7 Digital Inputs, 8 Outputs | RS485 MODBUS | DC 24V |
...
The following combination fulfills most common requirements.
Module | Description |
---|---|
X20BC0087 | MODBUS TCP |
X20PS9400 | Power Supply |
X20DI9372 | 12x Digital Inputs |
X20DO6639 | 6 Relays, 240 VAC |
X20AI4622 | 4x Analog Inputs, 4-20MA or 0-10V |
X20AP3131 | AC Meter, 480 VAC, 50/60 Hz, 5A sec. current |
Single modules
Vendor | Device | Comment | Connects via | Power |
Advantech | ADAM-6251-AE | 16 Digital Inputs Ethernet Module | Ethernet | DC 24V |
Advantech | ADAM-6217-AE | 8 Analogue Inputs Ethernet Module | Ethernet | DC 24V |
Advantech | ADAM-6250-AE | 7 Digital Inputs, 8 Outputs, Ethernet Module | Ethernet | DC 24V |
...
Vendor | Device | Comment | Connects via | Power | Number of Output Parameters | Output Parameters | |
Elkor | WattsOn-1100-MSCT2-600A | AC Power Meter | RS485 MODBUS | DC 24V | 50 |
| |
Elkor | MSCT2 | Current transducer for WattsOn, one per phase needed | To WattsOn (analog) | 1 | Current | ||
Elkor | i-Snail-S | Current Switched Sensor, monitoring on/off state of a device | Digital Input | 1 | Go/No-Go Signal | ||
Elkor | i-Snail-VC | AC current sensor | Analog Input | 1 | Voltage (DC, analog) |
DC Sensors
Vendor | Device | Comment | Connects via | Power | Number of Output Parameters | Output Parameters | Comments | |
CE-Transducers | AD11B-34GS4-1.0/0-250A*0-65V | DC mulit parameter monitoring (U,I,P,KWh) | RS485 MODBUS | DC 24V | 1 | Voltage | Wrong devide numer? Should start with CE | |
CE-Transducers | CE-AU11-34MS3-0.2/0-65V | 1-element DC Voltage Meter | RS485 MODBUS | DC 24V | 1 | Voltage |
Other Sensors
Enviromental
...
Vendor | Device | Comment | Connects via | Power | Number of Output Parameters | Output Parameters | ||
HIDGlobal | Proxpro 5355 | Keypad HIDGlobal Proxpro 5355 | Wiegand | DC 10-28.5V | ||||
Infranet | WTSC-485 | WTSC-485 Wiegand to RS-485 Converter (for Keypad) | RS485 MODBUS | DC 24V |
...
Providers
Vendor | WebPage | Email |
---|---|---|
Elkor | http://www.elkor.net/ | info@elkor.net |
CE Transducers | http://www.ce-transducer.com/ | sales@ce-transducer.com |
Advantech | http://www.advantech.eu/ | |
SimonsVoss | www.simons-voss.com | phil.andrew@simons-voss.com |
Holykell | http://www.holykell.com/ | jennifer@holykell.com |
AST | http://www.astsensors.com/ | info@astsensors.com |
B&R | http://www.br-automation.com/ | |
Ifm Electronic GmbH |