- Open the
> Configuration > Host Checks and select a command name for host checks (see picture below).Insert excerpt _AdminWeb _AdminWeb nopanel true Enter your settings or change it, as described in the table below.
Parameter
Description
Filter name
Filter name to be used as filter ID - must be unique. Allowed characters are a-z, A-Z, 0-9 and underscore (_).
Source address
Address of host sending the trap (empty address means that any source address is allowed to pass appropriate trap).
OID
Object Identifier (OID ) of the trap. If specified OID matches OID of appropriate trap or any of its bound data OIDs, the trap will be passed to the monitoring process.
Resulting service state
Service state created by determining passive check result for service matching trap parameters.
Following values are allowed: “OK”, “WARNING”, “CRITICAL”, “UNKOWN”