Table of Contents

...

Version
Date
Comment
Current Version (v. 34)35)Ago 05,2014 14:40

Marcos Moreno:

removed references to specific version 5.1.1a and 5.1.1b and referring 5.1.x to avoid client confusion.

v.34Jul 10, 2014 16:09Sebastian Koch:
Added note about fixed check_azetiplugin_netapp3, Added end of life for check_azetiplugin_kyocera_toner. Added not about check_radius_adv fix. Added Known Issues Table
v. 32Jul 09, 2014 10:25Sebastian Koch
Enhanced backup creation instructions
v. 29Jul 08, 2014 18:15Sebastian Koch
Added extra steps to disable notifications, flushing the mail queue and fixed minor typos
v. 25Jul 08, 2014 12:11Sebastian Koch
Extended list of incompatible plugins and known issues for EOL packages
v. 21Jul 01, 2014 15:31Sebastian Koch
Added Known Issues for Upgrade section regarding plugin update package
v. 18Jun 26, 2014 16:01Sebastian Koch
Fixed minor typos in portal paths, Added section about Plugin Download for azeti NG

...

 

After the SONARPLEX Upgrade

SONARPLEX 5 is a major release and thus some minor system configuration changes must be done right after the upgrade. 

Updating the LOAD Configuration

The following step assures that the global LOAD Configuration is properly updated and is mandatory.

  1. Insert excerpt
    _OpenAdminWeb
    _OpenAdminWeb
    nopaneltrue
     > Configuration > System > Load Configuration
  2. Choose  to save the current configuration and apply it with the following 

Configure the global Log Level

A whole new logging framework was introduced with the upgrade. See

Insert excerpt
_AdminWeb
_AdminWeb
nopaneltrue
 > Configuration > System > Logging Configuration.

 By default the Debug log level is set to OFF. We recommend turning it to INFO for all hardware types except the azeti NG.

Note

The azeti NG runs on SD flash storage and debug log levels can lead to decreased lifetime of the storage due to large amounts of write operations through logging. Therefore leave the Debug log level set to OFF.

Flush the Retention File

To warrant a consistent status among the old and new plugins, delete the retention file. 

Insert excerpt
_AdminWebDeleteRetention
_AdminWebDeleteRetention
nopaneltrue

Flush the Mail Queue

It is possible that during the upgrade system messages are created and stored in the email queue. Those would be sent out whenever you enable the SMTP configuration and you can flush those if you don't want to receive such mails from the upgrade.

Flushing queued e-mails:

  1. Insert excerpt
    _OpenAdminWeb
    _OpenAdminWeb
    nopaneltrue
     > System > Email Queue
  2. Choose  Delete all messages in queue and press OK

Re-Enable the Notifications

When all upgrade steps are done and the system behaves properly, it is save to enable the notifications again. Check that not too many service and host checks are in Non-OK states to avoid notification floods.

Insert excerpt
_UserWebEnableNotificationsGlobally
_UserWebEnableNotificationsGlobally
nopaneltrue

 

...