Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

 

Table of Contents

...

PackageFilenameDescriptionDownload

SONARPLEX 4.2 patch level 7

update-4.2.0b-base-7.tarenables upgrade from SONARPLEX 4.2.0b to 5.1.xazeti Portal > Downloads > SONARPLEX Generation 4 > Updates
SONARPLEX 5.1.1a image<SysID>-daaz1en-5.1.1a.aup (e.g. 2m002421121f36-daaz1en-5.1.1a.aup)Full Operating System image version 5.1.1aazeti Portal > My Appliances > <SONARPLEX SysId>
SONARPLEX 5.1.1a plugin updatesplugin-updates-001_v4.2.0b_to_v5.1.1a.tarPackage containing all necessary plugin updates for automatic installationazeti Portal > Downloads > SONARPLEX Generation 5 > Updates
SONARMANAGER 2.7.3.24SonarManager_2.7.3.24.zipSONARMANAGER compatible to SONARPLEX 5.x.xazeti Portal > Downloads > SONARPLEX Generation 4 5 > SONARMANAGER

System Backup

...

 

After the SONARPLEX Upgrade

SONARPLEX 5 is a major release and thus some minor system configuration changes must be done right after the upgrade. 

Configure the global Log Level

A whole new logging framework was introduced with the upgrade. See Admin GUI > Configuration > System > Logging Configuration.

 By default the Debug log level is set to OFF. We recommend turning it to INFO for all hardware types except the azeti NG.

Note

The azeti NG runs on SD flash storage and debug log levels can lead to decreased lifetime of the storage due to large amounts of write operations through logging. Therefore leave the Debug log level set to OFF.

Flush the Retention File

To warrant a consistent status among the old and new plugins, delete the retention file. 

Info

Deleting the retention file leads to a flush of all status information, this will set every host and service object into state PENDING. This is expected and the objects will be checked during the normal check intervals and return into a non-PENDING state.

Deleting the retention file:

  1. Open Admin GUI > Status > Monitor
  2. Choose Delete state retention file (read online help before using), the Monitor process will be restarted automatically

 

...